Skip to main content
Free second opinion on every case Doctor-checked quotes, free for patients
Updated Nov 2, 2026 Prices updated May 2026

ICD (Implantable Cardioverter Defibrillator) cost abroad (2026)

ICD (Implantable Cardioverter Defibrillator) costs from about $14,800 in India to $59,000 in Germany. Typical hospital prices from 72 price records across 9 countries. Pick a country to see its hospitals, surgeons and visa steps.

  • 2 nights in hospital
  • 14 days to full recovery
  • 9 countries compared
  • 96% reported success rate

Prices are hospital price ranges from our database, not a final quote. How we check

Estimate your total cost

Choose your options. The price updates straight away.

Country
Implant type est.
Hospital room est.
Hotel after discharge
Your hotel budget
Family members travelling
Hospital package$10,840 – $18,725
Hotel, 7 nights$420
Meals est.$240
Coordinator, visa letter helpFree
Estimated total$11,500 – $19,385

Hospital package = typical price range from 8 hospital prices.

Room and implant choices use rough adjustments (est.). Meals at about $15 per person per day. Flights not included.

Get 3 real quotes for this estimate

Top hospitals for ICD (Implantable Cardioverter Defibrillator) by country

How we rank

Ranked by accreditation, patient rating and review count, then price.

  1. Indraprastha Apollo Hospital 1
    Indraprastha Apollo Hospital
    New Delhi · India · ISO 9001 · JCI · NABH · ★ 4.9
    From
    $12,070
    ⁦$12,070 – $20,840⁩ 2 doctors listed JCI accredited
  2. Bumrungrad International 2
    Bumrungrad International
    Bangkok · Thailand · HA · ISO 9001 · JCI · ★ 4.8
    From
    $14,300
    ⁦$14,300 – $24,690⁩ JCI accredited
  3. Asan Medical Center 3
    Asan Medical Center
    Seoul · South Korea · ISO 9001 · JCI · KOIHA · ★ 4.8
    From
    $20,670
    ⁦$20,670 – $35,700⁩ 21 doctors listed JCI accredited
  4. Cleveland Clinic Abu Dhabi 4
    Cleveland Clinic Abu Dhabi
    Abu Dhabi · United Arab Emirates · DHA · DOH · JCI · ★ 4.7
    From
    $23,620
    ⁦$23,620 – $40,800⁩ JCI accredited
  5. Mount Elizabeth Hospital 5
    Mount Elizabeth Hospital
    Singapore · Singapore · ISO 9001 · JCI · ★ 4.7
    From
    $27,200
    ⁦$27,200 – $46,980⁩ JCI accredited
  6. Acıbadem Maslak Hospital 6
    Acıbadem Maslak Hospital
    Istanbul · Turkey · ISO 9001 · JCI · ★ 4.6
    From
    $14,860
    ⁦$14,860 – $25,670⁩ JCI accredited
Free report · PDF · PDF in English

Get the ICD (Implantable Cardioverter Defibrillator) cost & planning report

A free PDF built from today's listed prices. Keep it, print it or send it to your family on WhatsApp.

What's inside

  • Prices by country, city and hospital, compared with home
  • All-in trip budget: treatment, stay, food, visa
  • Day-by-day timeline and recovery milestones
  • Visa summary, preparation checklist and questions to ask
Preview from the report
Where the money goes · India
  • Treatment (typical listed price) 91% $14,800
  • Accommodation 4% $700
  • Food 3% $450
  • Local transport 1% $100
  • Visa fees 1% $150
  • Estimated total$16,200

Source: medcasts.com · prices as of May 2026

Free. No obligation. We never share your details with hospitals without asking you.

Not sure you need surgery?

Get a free second opinion in 48 hours.

Send your scans and reports. A senior specialist reviews them and replies in writing.

Upload my reports Photos from your phone are fine. Private and encrypted.

Top ICD (Implantable Cardioverter Defibrillator) surgeons

ICD (Implantable Cardioverter Defibrillator) prices by country

Typical hospital price per country, from 72 price records in the Medcasts database.

Get an email when ICD (Implantable Cardioverter Defibrillator) prices change We re-check listed prices every quarter. One email when they move. Nothing else unless you ask.

What a hospital quote usually includes

  • Surgeon, anaesthesia and operating room
  • About 2 nights in hospital, with nursing care
  • Routine tests and medicines during the stay
  • Free Medcasts coordinator, visa letter help and airport pickup arrangements
  • Not included: flights and hotel after discharge

Every quote we send lists what is and isn't included, line by line.

Your recovery plan

  1. Day 1Overnight observation, chest X-ray and device programming.
  2. Days 2–7Wound care; keep the arm below shoulder height.
  3. Weeks 2–6Gradual return to light activity; lifting limits remain.
  4. Weeks 6–12Normal activity and work; first device check.
  5. Months 3–12Regular checks; battery and lead monitoring.
Full recovery guide

Medical visa times by destination

Visa processing time by destination

We send the hospital invitation letter within 24 hours of your decision. Check your visa

About ICD (Implantable Cardioverter Defibrillator)

Under local anaesthesia with sedation, the doctor makes a small cut below the collarbone, guides one or two leads through a vein into the heart and connects them to a generator placed under the skin. The device is tested before you wake. A subcutaneous version can be placed without leads in the heart, and suits some younger people. The procedure takes about one to two hours.

An ICD does not prevent rhythm problems, but it treats them quickly and can be life-saving. Its benefit depends on the reason for implantation, whether it is for prevention or after a prior event, the underlying heart condition and the programming. Inappropriate shocks, lead problems and infection can occur, and the generator battery eventually needs replacing.

Plan to stay near the hospital for two to three days. Avoid lifting your arm above shoulder height for a few weeks, and ask about driving rules in your country. Keep the device card and bring your cardiology reports. Arrange a device clinic at home for regular checks, and share details of the brand and model.

Usually a good fit if

  • Survivors of cardiac arrest or dangerous ventricular rhythms (secondary prevention).
  • Weak heart pumping, often ejection fraction 35 percent or lower, at risk of dangerous rhythms despite medicines (primary prevention).
  • Inherited heart rhythm conditions with high risk.
  • A reasonable life expectancy beyond a year.

May need to wait if

  • Active infection, which must be treated first.
  • Reversible causes of the rhythm problem not yet treated.
  • Very advanced illness with limited life expectancy.
  • Inability to attend device checks.
How to prepare
  1. Have an ECG, echocardiogram, blood tests and chest X-ray; bring documentation of ejection fraction or arrhythmia history.
  2. Review blood thinners, heart and diabetes medicines with your doctor, who will tell you what to adjust.
  3. Report any infection, fever or skin problem near the chest.
  4. Fast for the hours the team specifies.
  5. Plan for a device identification card and remote monitoring set-up.
Questions to ask your surgeon
  1. Do I need an ICD alone, or CRT-D or a subcutaneous ICD?
  2. Which device and lead type will you use and why?
  3. What is my chance of receiving a shock?
  4. How do you reduce the risk of infection and lead problems?
  5. Can my home clinic follow this brand?
  6. What are my driving and work restrictions?
Red flags when comparing hospitals
  • ICD advised without echo or rhythm evidence supporting need.
  • No device clinic or remote monitoring arranged.
  • Brand chosen without explanation.
  • Infection prevention protocol not described.
  • Inadequate counselling about shocks.

Questions about ICD (Implantable Cardioverter Defibrillator) abroad

Which country is cheapest for ICD (Implantable Cardioverter Defibrillator)?

The lowest typical hospital prices are in India ($14,783), Thailand ($17,388), Turkey ($20,813), out of 9 countries we compare.

How long will I stay in hospital for ICD (Implantable Cardioverter Defibrillator)?

Most patients spend about 2 nights in hospital. Full recovery takes about 14 days; your surgeon will tell you when you are fit to fly home.

What does a shock feel like?

It feels like a sudden thump or kick in the chest. Contact your clinic after any shock, and call emergency services if you feel unwell or have repeated shocks.

How long does the battery last?

Often 5 to 10 years depending on use. The generator is changed in a smaller operation when low.

Can I drive?

Rules vary by country and depend on whether the ICD was implanted for prevention or after an arrest. Ask your cardiologist.

Can I have an MRI?

Many modern devices are MRI-conditional, but need special settings. Always tell staff about your device first.

Ready to compare real prices?

3 doctor-checked quotes in 48 hours. Free, and no obligation.